1.
Cancer Research on Prevention and Treatment ; (12): 474-478, 2021.
Article in Chinese | WPRIM | ID: wpr-988569

ABSTRACT

Objective To explore the dose of template-assisted 192Ir source hypofractionated stereotactic brachytherapy (SABT) for peripheral lung cancer. Methods We retrospectively analyzed the dose parameters of GTV and OARs of 28 peripheral lung cancer patients treated with template-assisted 192Ir-source hypofractionated SABT, and compared the dose parameters between SABT with virtual SBRT. Results The Dmean and V150 for the GTV in the SABT plan were significantly higher than those in the SBRT plan (all P < 0.01). For OARs, all dosimetric parameters in the SABT plan were significantly lower than those in the SBRT plan (all P < 0.01), except for the D1000cm3 and D1500cm3 for the lung (P > 0.05). Conclusion Template-assisted 192Ir source hypofractionated SABT ensures high dose in the gross tumor volume and reduces the dose in organs at risk in the treatment of peripheral lung cancer.

2.
Chinese Journal of Radiation Oncology ; (6): 1154-1158, 2021.
Article in Chinese | WPRIM | ID: wpr-910530

ABSTRACT

Objective:To evaluate the 3-year survival outcomes and late injury between the self-designed patent single-channel applicator, which was modified from the traditional tandem applicator and wrapped with a oval-shield alloy around the source channel and standard Fletcher-type applicator in the high-dose-rate brachytherapy for cervical cancer.Methods:Patients initially diagnosed with cervical cancer in the Affiliated Hospital of Southwest Medical University from December 2011 to April 2017 were enrolled and randomly assigned into the external beam radiotherapy (EBRT)+ single-channel intracavitary applicator group (the patent single-channel group) and EBRT+ the Fletcher applicator group. The whole pelvis irradiation was delivered with 6-MV photons via a four-field box variant or anterior and posterior parallel fields. Five to six fractions of intracavitary brachytherapy were performed at a dose of 7 Gy at point A once a week after 30 Gy (Equivalent Dose in 2 Gy at point A: 80-90 Gy). Chemotherapy was given with intravenous injection of cisplatin at a dose of 40 mg/m 2 once weekly during EBRT. Clinical efficacy and safety were evaluated after corresponding treatment. Results:In total, 150 eligible cases were assigned into the Fletcher applicator group and 149 cases into the patent single-channel group. Up to December 2020, all patients had been followed up for 3 years, and the median duration of follow-up was 61 months. In the Fletcher group, the 3-year overall survival, progression-free survival and locoregional failure-free survival was 76.3%, 78.1% and 75.4%, and 83.8%, 80.3% and 85.5% in the single-channel group, respectively. In the Fletcher group, the cumulative rate of grade 3-4 late rectal complications was 3.3% and 6.7% in the single-channel group ( P=0.122). The cumulative rate of grade 3-4 bladder complications was 1.3% in the Fletcher group and 0.7% in the single-channel group ( P=1.000). Conclusion:The self-designed patent single-channel intracavitary applicator yields equivalent long-term clinical efficacy and safety to the standard Fletcher-type three-channel applicator in the HDR brachytherapy for uterine cervical cancer.

3.
Chinese Journal of Radiation Oncology ; (6): 753-758, 2018.
Article in Chinese | WPRIM | ID: wpr-807142

ABSTRACT

Objective@#To evaluate whether the self-designed single-channel intracavitary applicator yields equivalent clinical efficacy and safety to the standard Fletcher-type three-channel applicator in the high-dose-rate (HDR) brachytherapy for uterine cervical cancer.@*Methods@#From December 2011 to April 2017, patients initially diagnosed with cervical cancer were randomly assigned into the external beam radiotherapy (EBRT)+ single-channel intracavitary applicator group (the patent single-channel group) and EBRT+ the Fletcher applicator group. Whole pelvis irradiation was delivered with 6-MV photons via a four-field box variant or anterior and posterior parallel fields. Five to six fractions of intracavitary brachytherapy were performed at a dose of 7 Gy at point A once a week after 30 Gy (BED at point A: 80-90 Gy). Chemotherapy was given with intravenous injection of cisplatin at a dose of 40 mg/m2 once weekly during EBRT.Clinical efficacy and safety were evaluated after the treatment.@*Results@#In total, 150 eligible cases were assigned into the Fletcher applicator group and 149 cases into the patent single-channel group. The short-term clinical efficacy and acute toxicity did not significantly differ between two groups. The response rate was 94.0% in the Fletcher group, and 94.7% in the patent single-channel group. In the Fletcher applicator group, 76(50.7%) patients developed ≥ grade 3 hematologic toxicity and 61(40.9%) in the patent group (P=0.195).@*Conclusions@#The self-designed patent single-channel intracavitary applicator yields equivalent clinical efficacy and safety (acute toxicity) to the standard Fletcher-type three-channel applicator in the HDR brachytherapy for uterine cervical cancer.@*Clincal Trial Registration@#Chinese Clinical Trial Registry (ChiCTR-TRC-12002321).